BSD-B2000 / BSD-BI2000
BSD-B2000 / BSD-BI2000 brushless DC screwdrivers: model-specific torque, speed, voltage, compatible controllers and original catalogue. Request a quotation from KILEWS Thailand.
Models: SKD-BE512P · SKD-BE512PF · SKD-BE517PF · SKD-BE519PThe SKD-BE500P push-to-start series combines a brushless DC screwdriver with an integrated screw counter. The specification table also lists lever-start L models for comparison. Confirm available models and the matching power controller with KILEWS Thailand.
Technical documents8 filesPrice and lead time are confirmed by model, quantity and project requirements.
Product features
Model | Torque(kgf.cm) | Torque (Lbf.in) | Torque (N.m) | Accuracy (%) | No-load Speed(r.p.m) HI | No-load Speed(r.p.m) LO | Screw Diameter(mm) Machine Screws | Screw Diameter(mm) Self-tapping Screws | Weight (g) | Length (mm) | Compatible Power Controller | Compatible Bit Types |
SKD-BE512L | 1.5~12 | 1.32~10.56 | 0.15~1.18 | ±3% | 1000 | 700 | 1.6~3.0 | 1.6~2.6 | 580 | 270 | SKP-32BC-60W(N) | A、B、C、D |
SKD-BE512P | 2~12 | 1.76~10.56 | 0.19~1.18 | ±3% | 1000 | 700 | 1.6~3.0 | 1.6~2.6 | 580 | 270 | SKP-32BC-60W(N) | A、B、C、D |
SKD-BE512LF | 1.5~12 | 1.32~10.56 | 0.15~1.18 | ±3% | 2000 | – | 1.6~3.0 | 1.6~2.6 | 580 | 270 | SKP-BE32HL(N) | A、B、C、D |
SKD-BE512PF | 2~12 | 1.76~10.56 | 0.19~1.18 | ±3% | 2000 | – | 1.6~3.0 | 1.6~2.6 | 580 | 270 | SKP-BE32HL(N) | A、B、C、D |
SKD-BE517LF | 3~17 | 2.64~14.96 | 0.29~1.67 | ±3% | 2000 | – | 1.6~3.0 | 1.6~2.6 | 580 | 270 | SKP-BE32HL(N) | A、B、C、D |
SKD-BE517PF | 3~17 | 2.64~14.96 | 0.29~1.67 | ±3% | 2000 | – | 1.6~3.0 | 1.6~2.6 | 580 | 270 | SKP-BE32HL(N) | A、B、C、D |
SKD-BE519L | 3~19 | 2.64~16.72 | 0.29~1.86 | ±3% | 1000 | 700 | 2.3~3.5 | 2.3~3.0 | 580 | 270 | SKP-32BC-60W(N) | A、B、C、D |
SKD-BE519P | 3~19 | 2.64~16.72 | 0.29~1.86 | ±3% | 1000 | 700 | 2.3~3.5 | 2.3~3.0 | 580 | 270 | SKP-32BC-60W(N) | A、B、C、D |
The Thailand table retains the controller (N) suffix; the current headquarters table omits it. Confirm the actual supplied revision, cable, connectors, power supply and included accessories with sales. Similar names or voltage alone do not establish interchangeability.
The BE500 Thailand table lists bit codes A, B, C and D. Confirm the supplied holder, shank/profile, retention and working length before ordering.
P/PF are push-to-start; L/LF use a lever/trigger. Their torque limits can differ: BE512P starts at 0.19 N.m, while BE512L starts at 0.15 N.m.
BE512P and BE519P list HI/LO 1000/700 rpm with SKP-32BC-60W(N). BE512PF and BE517PF list HI 2000 rpm, a dash for LO, and SKP-BE32HL(N). A dash is not a 0 rpm specification.
The integrated LED counter and timing checks do not establish per-joint measured torque/angle or traceability. Verify the actual configuration and any required PLC/MES interface or recording package.
Provide the full model, target torque and unit, quantity, start method, existing controller/cable/bit, company, delivery location and required date. Price and stock require confirmation. After PO, the usual 30–45 days cover order processing, transport and customs; sales confirms the day basis and start conditions.
Reviewed against the existing Thailand/Chinese table and current headquarters specifications. Thailand (N) suffixes are retained pending confirmation of the supplied configuration.
KILEWS headquarters BE500P · Original Chinese table · หน้าสินค้าภาษาไทย
Content reviewed 21 October 2026