KTM-150
SpecificationsModelKTM-1000KTM-250KTM-150KTM-15KTM-6KTM-50SMeasurement range(kgf.cm)50~10003.0~250.01.5~150.00.15~15.00.02~8.00.5~
0.15–15.0 N·m
KTM-150 — Torque tester. Review model-specific specifications below and confirm the exact configuration with KILEWS Thailand.
Price and lead time are confirmed by model, quantity and project requirements.
Torque tester
Compare the model-specific parameters in the specification table.
Confirm compatible accessories, document version and Thailand availability before ordering.
Model | KTM-1000 | KTM-250 | KTM-150 | KTM-15 | KTM-6 | KTM-50S |
Measurement range(kgf.cm) | 50~1000 | 3.0~250.0 | 1.5~150.0 | 0.15~15.0 | 0.02~8.0 | 0.5~50.0 |
Measurement range(Lbf.in) | 45~885 | 3.0~217.0 | 1.5~130.0 | 0.15~13.0 | 0.02~7.0 | 0.5~43.4 |
Measurement range(N.m) | 5~100 | 0.30~25.00 | 0.15~15.0 | 0.015~1.500 | 0.2~80.0(cN.m) | 0.05~4.90 |
Accuracy | +/-0.5%(20~100N.m), +/-1.0%(10~20N.m), +/-2.0%(5~10N.m) | +/-0.5% | +/-0.5% | +/-0.5% | +/-0.5% | +/-0.5% |
Power supply | 3.7V,4400mAh Lithium lon | 4.8VDC (Ni-MH chargeable battery 1.2VX4 cell 1650mAh) | 4.8VDC (Ni-MH chargeable battery 1.2VX4 cell 1650mAh) | 4.8VDC (Ni-MH chargeable battery 1.2VX4 cell 1650mAh) | 4.8VDC (Ni-MH chargeable battery 1.2VX4 cell1650mAh) | 4.8VDC (Ni-MH chargeable battery 1.2VX4 cell1650mAh) |
Charging time | 8 hours | 3 hours | 3 hours | 3 hours | 3 hours | 3 hours |
Operating time per full charge | 8 hours | approx. 12 hours | approx. 12 hours | approx. 12 hours | approx. 12 hours | approx. 12 hours |
Battery life | Rechargeable for more than 300 cycles | Rechargeable for more than 300 cycles | Rechargeable for more than 300 cycles | Rechargeable for more than 300 cycles | Rechargeable for more than 300 cycles | Rechargeable for more than 300 cycles |
Overall dimensions (mm) | 229X102X80(H) | 160X210X45(H) | 230X125X65(H) | 230X125X65(H) | 230X125X65(H) | 230X123X65(H) |
Weight(kg) | 2.7 | 2.0 | 1.8 | 1.8 | 1.8 | 1.8 |
Dedicated charger | Input AC100V~240V 50/60Hz Output DC5V1.0A Max | Input AC100V~240V 50/60Hz Output DC12V 400Ma | Input AC100V~240V 50/60Hz Output DC12V 400mA | Input AC100V~240V 50/60Hz Output DC12V400mA | Input AC100V~240V 50/60Hz Output DC12V400mA | Input AC100V~240V 50/60Hz Output DC12V400mA |
Accessories | Spring test fixtureX1, SJ-100N.m | Spring test fixtureX1, AJ-250 | Spring test fixtureX3, AJ-150/AJ-50/AJ-15K | Spring test fixtureX2, AJ-15/AJ-3 | Spring test fixtureX1, AJ-3 | Spring test fixtureX1, AJ-50S |
The table lists ±0.5% accuracy. Confirm the calibration conditions, reference basis, acceptance range and whether a requested certificate is included. Instrument accuracy, a tool acceptance decision and a calibration certificate are separate matters.
The published set lists AJ-150, AJ-50 and AJ-15K spring test joints, one each. Confirm the required torque/unit, permitted range of the selected joint, spring arrangement, shaft/bit connection, fixture mounting and supplied set. Do not assume every joint can be used across the instrument’s full range.
Confirm the actual battery/charger nameplate, manual revision, USB interface, compatible software/OS, data fields and cable inclusion. A bench torque check does not automatically create per-screw production torque/angle records or MES traceability.
No. The published range is 0.15–15.0 N·m; 150.0 appears in the kgf·cm column.
Not automatically. Specify certificate scope, traceability and conditions in the quotation, along with the appropriate test joints.
※Scroll horizontally to read the table
No dedicated accessories are listed on the headquarters page. Confirm with KILEWS Thailand.
Our Thailand team helps with tool selection and system matching.